1.Our pumps could be 100% interchangeble with leading enterprise’s 3196 series.
2.The wet ends material like Titanium, Nickel, Hastelloy C, A20, CD4M, 316SS, Cast Steel etc are all available.
Centrifugal Pump.
• Model 3196.
• S/N 788B861.
• Size 1 in. x1-1/2 in. x 8 in.
• Water flush double mechanical seals. Motor 1.5 hp, 1,730 rpm, 230/460 V, 60 Hz, 5.6/2,8
amps, 3 phase, Capacity 14 gpm.
• Overall Dimensions 35 in. L x 12 in. W x 15 in. H.
Pump Safety Tips
Safety Apparel:
Insulated work gloves when handling hot bearings or using bearing heater
Heavy work gloves when handling parts with sharp edges, especially impellers
Safety glasses (with side shields) for eye protection, especially in machine shop areas
Steel-toed shoes for foot protection when handling parts, heavy tools, etc.
Other personal protective equipment to protect against hazardous/toxic fluids
Coupling Guards:
Never operate a pump without a coupling guard properly installed
Flanged Connections:
Never force piping to make a connection with a pump
Use only fasteners of the proper size and material
Ensure there are no missing fasteners
Beware of corroded or loose fasteners
Operation:
Do not operate below minimum rated flow, or with suction/discharge valves closed
Do not open vent or drain valves, or remove plugs while system is pressurized
Maintenance Safety:
Always lock out power
Ensure pump is isolated from system and pressure is relieved before disassembling pump,removing plugs, or disconnecting piping
Use proper lifting and supporting equipment to prevent serious injury
Observe proper decontamination procedures
Know and follow company safety regulations
Observe all cautions and warnings highlighted in pump Installation, Operation and Maintenance