ANSI pumps enhancements
With special attention to materials and component options our pumps can be used to handle liquids ranging in
temperature from as low as -200°F (-129°C) to as high as 700°F (371°C).
It is always essential that the pressure and temperature of the application never exceed the pressure/temperature
limits of the pump.
Operation at either low or high temperatures could require modification of the standard pump design to provide strength of materials for pressure containment and resistance to thermal shock, a method for cooling or heating pump components, mechanical seal protection, special gaskets, and/or maintenance of pump/motor shaft alignment.
The Ultralign C-flange motor adapter is recommended on any application with temperature fluctuations of more than 100°F(38°C).